研究業績

研究業績

achievement

TOP / 研究業績 / 2014年 / Page 4
2014年

False

原著論文

その他

Toma K, Kano H, Offenhäusser A, Label-free measurement of cell-electrode cleft gap distance with high spatial resolution surface plasmon microscopy, ACS Nano, 8(12), 12612-12619, 2014. (10.1021/nn505521e)

False

原著論文

バイオスニファ

Saito H, Goto T, Miyajima K, Munkhjargal M, Arakawa T, Mitsubayashi K, Odourless Watermark (Digital Chemocode) System with Biochemical Sniff Scanner, Sensors and Materials, 26(3), 109-119, 2014. (10.18494/SAM.2014.948)

False

原著論文

その他

Gessei T, Arakawa T, Kudo H, Saito H, Mitsubayashi K, Amperometric Biosensor based on Enzyme Immobilization with Post Process for Medical and Multiple Applications, Analytical Letters, 47(8), 1361-1374, 2014. (10.1080/00032719.2013.867496)

False

原著論文

免疫センサ

Miyajima K, Suzuki Y, Miki D, Arai M, Arakawa T, Shimomura H, Shiba K, Mitsubayashi K, Direct analysis of airborne mite allergen (Der f1) in the residential atmosphere by chemifluorescent immunoassay using bioaerosol sampler, Talanta, 123, 241-246, 2014. (10.1016/j.talanta.2013.11.033)

False

原著論文

バイオアクチュエータ

Sato R, Hatayama K, Munkhjargal M, Matsuura Y, Arakawa T, Kudo H, Mitsubayashi K, Improvement of decompression unit in autonomous drug release system for blood sugar control, Journal of Advanced Science, 24, 21-23, 2012. (10.2978/jsas.24.21)

True

国際学会

Mitsubayashi K, Real time gas-imaging with enzyme mesh for breath ethanol after drinking, The 15th International Meeting on Chemical Sensors (IMCS 2014), Buenos Aires, Argentina, March 16-19, 2014.

False

国際学会

Miyajima K, Suzuki Y, Miki D, Arai M, Arakawa T, Shimomura H, Mitsubayashi K, Airborne allergen determination for Der f1 by chemifluorescent immunoassay with bioaerosol sampler, The 15th International Meeting on Chemical Sensors (IMCS 2014), Buenos Aires, Argentina, March 16-19, 2014.

False

国際学会

Arakawa T, Wang W, Sato T, Miyajima K, Munkhjargal M, Mitsubayashi K, Optical imaging of breath ethanol using real time biochemical luminescence for evaluation of alcohol metabolic capability, EUROPT(R)ODE XII, Greece, April 13-16, 2014.

False

国際学会

Munkhjargal M, Sato R, Takagi H, Matsuura Y, Hatayama K, Arakawa T, Mitsubayashi K, Glucose powered “Organic Engine” (chemo-mechanical device) with multi-enzymatic amplification for autonomous drug release system (artificial pancreas), Biosensors 2014, Melbourne, Australia, May 27-30, 2014.

False

国際学会

Arakawa T, Wang X, Kajiro T, Miyajima K, Yano K, Mitsubayashi K, Direct imaging system of gaseous ethanol from exhaled human breath for non-invasive analysis of alcohol metabolism, Biosensors 2014, Melbourne, Australia, May 27-30, 2014.

False

国際学会

Sato T, Wang X, Miyajima K, Toma K, Munkhjargal M, Arakawa T, Mitsubayashi K, Breath alcohol imaging with enzyme mesh after drinking, Breath Analysis 2014, Torun, Poland, July 6-9, 2014.

False

国際学会

Munkhjargal M, Sato R, Takagi H, Miyajima K, Arakawa T, Mitsubayashi K, Biocatalysis-based chemo-mechanical actuator for autonomous drug release system for blood sugar control in Diabetes, IUMRS-ICA 2014, Fukuoka, Japan, August 24-30, 2014.

False

国際学会

Arakawa T, Wang X, Miyajima K, Munkhjargal M, Mitsubayashi K, 2-dimensional gaseous ethanol visualization system for noninvasive analysis of alcohol metabolism from exhaled human breath, IUMRS-ICA 2014, Fukuoka, Japan, August 24-30, 2014.

False

国際学会

Jen Chien P, Ye M, Miyajima K, Arakawa T, Mitsubayashi K, 2-dimensional gaseous ethanol visualization system for noninvasive analysis of alcohol metabolism from exhaled human breath, IUMRS-ICA 2014, Fukuoka, Japan, August 24-30, 2014.

False

国際学会

Suzuki Y, Miyajima K, Arai M, Arakawa T, Shimomura H, Shiba K, Mitsubayashi K, Fiber-optic chemifluorescent immunoassay system for measurement of mite allergen Der f1, IUMRS-ICA 2014, Fukuoka, Japan, August 24-30, 2014.

False

国際学会

Arakawa T, Kita K, Wang X, Miyajima K, Toma K, Mitsubayashi K, Gaseous ethanol imaging systemfrom human breath and skin for evaluation of alcohol metabolism, Bio4Apps 2014, Shanghai, China, November 17-19, 2014.

False

国際学会

Jen Chien P, Miyajima K, Munkhjargal M, Toma K, Arakawa T, Kudo H, Mitsubayashi K, Highly sensitive fiber-optic formaldehyde gas sensor (biosniffer) for food-sample detection, Bio4Apps 2014, Shanghai, China, November 17-19, 2014.

False

国際学会

Miyajima K, Arai M, Toma K, Arakawa T, Shimomura H, Mitsubayashi K, Fiber-optic Immunosensing device for house dust mite allergen in air, Bio4Apps 2014, Shanghai, China, November 17-19, 2014.

False

国際学会

Arakawa T, Sato T, Wang X, Kita K, Munkbayar M, Toma K, Mitsubayashi K, “Scent camera” for real-time imaging of breath (body) ethanol after alcohol drinking, DOS 2014, Tokyo, Japan, December 8-9, 2014.

False

国際学会

Jen Chien P, Mori H, Ye M, Toma K, Sawada S, Arakawa T, Akiyoshi K, Mitsubayashi K, Bio-sniffer (biochemical gas sensor) with fiber-optic fluorometry for odorless formaldehyde vapor in residential atmosphere, DOS 2014, Tokyo, Japan, December 8-9, 2014.